Particle Counter

The AirShieldä ParticleScanCR is an advanced six (6) channel laser particle counter specifically designed to monitor and verify cleanrooms.  It has an ultra-fast sampling time of one (1) second.  This unit is ideal for quickly determining the ISO rating of any room.  It’s provided with window-based soft-ware and USB cable to interface into either a laptop or desktop, windows based computer system.

The AirShieldä ParticleScanPro, like the CR model, is an advanced six (6) channel laser particle counter specifically designed to monitor and verify cleanrooms.  It has a sampling time of six (6) seconds.  This unit is also ideal for quickly determining the ISO rating of any room.  It’s provided with window-based soft-ware and USB cable to interface into either a laptop or desktop, windows based computer system.

The AirShieldä ParticleScanLite is a one (1) channel (0.3 particle size only) laser particle counter.  Ideal for determining HVAC system and filter leakage.  It’s provided with window-based soft-ware and USB cable to interface into either a laptop or desktop, windows based computer system


Single Stage Air Sampler

The single stage, N6 type, microbial impactor was specifically designed by NIOSH researchers to meet the specifications of the latest ACGIH Bioaerosol Committee concerning sampling protocol, EPA, OSHA and FDA reference the N6 Cascade Impactors in their particle sizing protocols.                        

The N6 is comprised of an aluminum inlet cone, jet stage, and a base plate held together by three spring clamps and sealed with O-ring gaskets.  The jet stage has 400 precision machined jet orifices.  This Single Stage Viable Impactor requires a flow rate of exactly 28.3 lpm (1 CFM) to achieve the well documented cut-off diameter of 0.65 µm. This sample can be utilized for;

Indoor air quality studies, Pharmaceutical production,  Animal care laboratories, Wastewater treatment plants, Cosmetic manufacturing, Filter and clean room efficiency studies Pharmacy cleanroom compounding areas,  Food processing area, Hospital environments, Grain processing and transportation, Agricultural emissions


Room Pressure Monitors

TRRM Room Pressure Monitor

The TRRM Room Pressure Monitor is an advance compact control module that continuously monitors and/or controls room pressure and environment. The TRRM incorporates a bright colorful touch LCD screen interface to display a room's pressure status along with its pressure reading accurate to 0.001" Water Column. This monitor / controller is designed to be either recessed or surface mounted wherever monitoring is required. The TRRM gives personnel a clear, accurate, and unambiguous indication of its environment and alarm status.

The TRRM is capable of integration with building automation systems thru its onboard RS-485 Communication port or optional Daughter board.  All menus are accessed through the intuitive touch screen that allows the user to quickly configure for the TRRM to monitor and/or control critical rooms.

Dimensions:

                        • Face plate: Height 5”, Width 6.5”, Depth 3.5”

                        • LCD Touch Screen: 4" Diagonal

• Optional 5.7” screen available

Network / Communications:

                        • RS485 physical network

                        • BACnet MS / TP

                        • MODBUS

                        • N2 – Johnson Controls

Differential Pressure Sensing / Controlling:

                        • Input signal options – 0 – 5 volts, 0-10 volts, 4-20mA, and Network – (.001” WC)

                        • Optional analog signal mirroring DP reading out to BAS (0-5 volts or 0-10 volts)

                        • Optional Pressure Control (PID) via dedicated 4-20mA (normal / reverse acting)

Temperature Sensing / Controlling:

                        • Input signal options – 0 – 5 volts, 0-10 volts, 4-20mA, and Network – (.1*)

                        • Optional Reheat Control (PID) via dedicated 0-5 volts or 0-10 volts (normal / reverse acting)

                        • Show / hide Temp and/or Temp Set Point on main screen

                        • Allow user to change Temp Set Point via password protected screen

TKFMS-1630 Room Pressure Monitor

With current concerns for airborne pathogen containment in negatively or positively pressurized in various medical procedure rooms it is imperative to be able to confirm those required pressures.

Additionally, the concern with either natural occurring disease pandemics or aerosolized bio-chemical contamination it is critical to be able to confirm proper differential pressure levels in isolation rooms. The TKFMS-1630 series of pressure monitors meet or exceed all published AIA, CDC, JCAHO and HICPAC-2003 guidelines, standards and regulations. 

  

Electrical
Power Supply (provided) - 24 VAC/DC ±10%, 10 VA

Remote Sensor Distance - 4,000 feet max.

Remote Sensor Wiring - 18-22 AWG twisted shielded  copper pair

120 VAC to 24 VDC Power Supply Provided

 
Mechanical

LCD Display - 4-Line x 16 characters per line

LCD Character Height - 0.19 inches

Mounting

TKFMS1630-D or R......    Surface / Flush optional
Flow Tube Cover Plate....   Flush Optional

External Remote Room Pressure Sensor ..........  Flush Mounted

Provides new standards now required for room pressure monitors showing:

     Differential pressure (dP) in digital numerics 24/7

     Flow direction

     Audible alarm when room pressure approaches ambient or reference pressure

 

Visual alarm when room pressure approaches ambient barometric or reference pressure

 

Can directly interface with in-house building digital automation information.  Systems is accurate to within ±0.001 inches of WC with NIST traceable standards

 

Can be flush mounted to the wall or simply mounted on the wall

 

Is simple to install usually by house maintenance staff or electrician

 

Provided by a nationwide company specializing in medical related indoor air quality issues for the healthcare industry

 

Company can provide for customer support number, availability 24/7

 

Small conservative wall fixture, a compact, (4” W x 6” H x 2” D) unit Is available for direct access to negative or positive pressure rooms (TKFMS1630D) or a remote model for room/s with anterooms or other sites, (TKFMS1630R). Is also available as a dual sensor model TKFMS1630-R2 for measuring two rooms simultaneously with one unit.

 

All models are available as LON modified (TKFMS1630L-R2) for interfacing with other systems.

 

Adjustable time delay for alarms allowing patients or staff moving in or out of room

 

Console panel for remote installation and monitoring at nursing station is available as an option

 

Alpha/numeric programmable LCD readout on face of the control panel

 

Stainless steel senor panel covers for both reference site and sensing site

PCPM1000 Room Pressure Monitor

Basic Room Pressure Monitor

The PCPM1000 monitor meets or exceeds all published AIA, CDC, JCAHO and HICPAC-2003 guidelines, standards and regulations.

 

Electrical
Power Supply (provided) - 120 VAC to 24 VAC/DC

Remote Sensor Distance - 400 feet max.

Remote Sensor Wiring - 18-22 AWG twisted shielded  copper pair

120 VAC to 24 VDC Power Supply Provided

 
Mechanical

LCD Display - 4-digit LED x 8 characters

LCD Character Height - 0.5 inches

Mounting

PCPM1000......    Surface / Flush optional
Flow Tube Cover Plate....   Flush Optional

External Remote Room Pressure Sensor ..........  Flush Mounted

Provides new standards now required for room pressure monitors showing:

     Differential pressure (dP) in digital numerics 24/7

     Flow direction

     Audible alarm when room pressure approaches ambient or reference pressure

 

Visual alarm when room pressure approaches ambient barometric or reference pressure

 

Can directly interface with in-house building digital automation information.  System is accurate to within ±0.001 inches of WC with NIST traceable standards

 

Can be flush mounted to the wall or simply mounted on the wall

 

Is simple to install usually by house maintenance staff or electrician

 

Provided by a nationwide company specializing in medical related indoor air quality issues for the healthcare industry

 

Company can provide for customer support number, availability 24/7

 

Small conservative wall fixture, a compact, (9.5"W x 5.5"H x 2.0"D) unit I

 

Adjustable time delay for alarms allowing patients or staff moving in or out of room

 

Console panel for remote installation and monitoring at nursing station is available as an option

 

Alpha/numeric programmable LED readout on face of the control panel

 

Stainless steel senor panel covers for both reference site and sensing site

AirShield™ DY475-000, Portable Digital Manometer

This hand-held portable manometer is a compact, bi-directional, battery-operated, digital manometer with excellent sensitivity and stability down to 0.001"of water column (or 0.1 Pascal). The sensing element is a proprietary, highly sensitive, differential capacitance cell, designed to operate at extremely low pressures.  This sensing element has been used for many years in other pressure transmitters and has proved to be most reliable.  This sensing element is used for pressures below 1.00 inch of water column.  Pressures greater than 1 inch of water is sensed by the latest silicon based technology.

Performance

Electrical Connections

Resolution:  0-1.00 in W.C. (0-.249 kPa)

Low battery indicator: “BAT" appears on the display

Accuracy: ± 0.5% FS 60 to 78degrees

Battery: One (1) 9 Volt alkaline… not included

                 ± 1.5% FS 32 to 60 degrees

Battery life: 100 hours

                 ± 1.5% FS 78 to 104 degrees            

Physical

Pressure Hysteresis: ± 0.1% of full scale

Display: LCD, .1/2" digit height

Pressure Limits: 10 in. W. C.

Controls: ON/OFF switch, English-Metric unit selection readout

Zero Adjustment: Zero adjustment knob at top

Physical dimensions: 6-9/16”H, 2-13/16”W and 29/32”D

 Environmental

Operating temp. range: 32 °F to 104°F

Operating temp. range: 32 °F to 104°F

Display: LCD, .1/2" digit height

Storage temp. range: -4 °F to 176 °F

Weight: 10.8 oz (306 g)

 

UV-C Radiometer

The X9 radiometer is a universally applicable measuring instrument for the determination of UV-C irradiance at 254 nm with direct read-out in the units of µW/cm2.  The meter is used together with the UV-3718 detector head to measure irradiance and dose in the UV-C spectral range at 254nm. Despite its compact dimensions, the meter offers a large display and an RS 232 interface. Operation is simple for the benefit of non-technical personnel.

This unit ships complete with a protective case for the meter and detector head.

 

Instrument Specifications

  • Max. irradiance value · 1000 mW/cm2
  • Max. resolution · 0.001 µW/cm2
  • Dose range · 0.00001 J/cm2 to 100,000 J/cm2
  •  

Optometer Specifications:

  • Display · LCD, 6 characters, 9 mm high
  • Detector connection · 9 pol. MDSM9 socket, two measurement input
  • Measurement ranges · 9, selected automatically
  • Integration time · 500 ms
  • Operating modes· CW, Dose, Run/Stop, Peak
  • Dosage measurement · Integration of the measured values at 1s/100ms intervals, Start/Stop by key-press
  • Offset · Offset compensation over all ranges
  • Operation · 3 buttons, settings stored in eeprom
  • Interface · RS232 (9600B, 8D, 1S, N), 8 pin plug (Hirose, type 3260-8S!)
  • Power · 9V one-piece battery (operating time about 100 hrs)
  • Temperature range · 5 to 40°C (41-104°F)
  • Size / Weight · 120 mm x 65 mm x 22 mm / 150g (4.7 in x 2.6 in x 1 in / 0.3 lb)

Home MAS APS Units Portable APS Construction APS UVGI Units Portable Units Honeywell APS Instruments Pass-throughs Refrigerators Surgical Suites Consulting Special Buildings Service MAS Home

 