HVAC and IAQ Instrumentation
Particle Counter
|
The AirShieldä
ParticleScan™
CR
is an
advanced six (6) channel laser particle counter specifically
designed to monitor and verify cleanrooms. It has an
ultra-fast sampling time of one (1) second. This unit is ideal
for quickly determining the ISO rating of any room. It’s
provided with window-based soft-ware and USB cable to interface into
either a laptop or desktop, windows based computer system.
The AirShieldä
ParticleScan™
Pro, like the CR model, is an advanced six (6) channel laser
particle counter specifically designed to monitor and verify
cleanrooms. It has a sampling time of six (6) seconds.
This unit is also ideal for quickly determining the ISO rating of
any room. It’s provided with window-based soft-ware and USB
cable to interface into either a laptop or desktop, windows based
computer system.
The AirShieldä
ParticleScan™
Lite
is a
one (1) channel (0.3 particle size only) laser particle counter.
Ideal for determining HVAC system and filter leakage. It’s
provided with window-based soft-ware and USB cable to interface into
either a laptop or desktop, windows based computer system |
|
Single Stage Air Sampler
The single stage, N6 type, microbial
impactor was specifically designed by NIOSH researchers to meet the
specifications of the latest ACGIH Bioaerosol Committee concerning sampling
protocol, EPA, OSHA and FDA reference the N6 Cascade Impactors in their particle
sizing protocols.
 |
The N6
is comprised of an aluminum inlet cone, jet stage, and a base plate held
together by three spring clamps and sealed with O-ring gaskets. The jet
stage has 400 precision machined jet orifices. This Single Stage Viable
Impactor requires a flow rate of exactly 28.3 lpm (1 CFM) to achieve the
well documented cut-off diameter of 0.65 µm. This sample can be utilized
for;
Indoor air quality studies, Pharmaceutical
production, Animal care laboratories, Wastewater treatment plants,
Cosmetic manufacturing, Filter and clean room efficiency studies
Pharmacy cleanroom compounding areas, Food processing area,
Hospital environments, Grain processing and transportation, Agricultural
emissions |
Room Pressure Monitors
TRRM Room
Pressure Monitor
The TRRM Room Pressure Monitor
is an advance compact
control module that continuously monitors and/or controls room pressure and
environment. The TRRM incorporates a bright colorful touch LCD screen
interface to display a room's pressure status along with its pressure reading
accurate to 0.001" Water Column. This monitor / controller is designed to be
either recessed or surface mounted wherever monitoring is required. The TRRM
gives personnel a clear, accurate, and unambiguous indication of its environment
and alarm status.
The TRRM is capable of integration
with building automation systems thru its onboard RS-485 Communication port or
optional Daughter board. All menus are accessed through the intuitive touch
screen that allows the user to quickly configure for the TRRM to monitor
and/or control critical rooms.
|
Dimensions:
|
|
• Face plate: Height
5”, Width 6.5”, Depth 3.5” |
|
• LCD Touch Screen:
4" Diagonal |
|
• Optional 5.7” screen available |
|
 |
|
Network /
Communications: |
|
• RS485 physical
network |
|
• BACnet MS / TP
|
|
• MODBUS
|
|
• N2 – Johnson
Controls |
|
|
Differential
Pressure Sensing / Controlling: |
|
• Input signal
options – 0 – 5 volts, 0-10 volts, 4-20mA, and Network – (.001”
WC) |
|
• Optional analog
signal mirroring DP reading out to BAS (0-5 volts or 0-10 volts)
|
|
• Optional Pressure
Control (PID) via dedicated 4-20mA (normal / reverse acting)
|
|
|
Temperature Sensing
/ Controlling: |
|
• Input signal
options – 0 – 5 volts, 0-10 volts, 4-20mA, and Network – (.1*)
|
|
• Optional Reheat
Control (PID) via dedicated 0-5 volts or 0-10 volts (normal /
reverse acting) |
|
• Show / hide Temp
and/or Temp Set Point on main screen |
|
• Allow user to
change Temp Set Point via password protected screen |
|

TKFMS-1630
Room Pressure Monitor
|
With current
concerns for airborne pathogen containment in negatively or positively
pressurized in various medical procedure rooms it is imperative to be
able to confirm those required pressures.
Additionally, the
concern with either natural occurring disease pandemics or aerosolized
bio-chemical contamination it is critical to be able to confirm proper
differential pressure levels in isolation rooms. The TKFMS-1630
series of pressure monitors meet or exceed all published AIA,
CDC, JCAHO and HICPAC-2003 guidelines, standards and regulations.

Electrical
Power
Supply (provided) - 24 VAC/DC ±10%, 10 VA
Remote Sensor
Distance - 4,000 feet max.
Remote Sensor
Wiring - 18-22 AWG twisted shielded copper pair
120 VAC to 24
VDC Power Supply Provided |
Mechanical
LCD Display -
4-Line x 16 characters per line
LCD Character
Height - 0.19 inches |
Mounting
TKFMS1630-D or
R...... Surface / Flush optional
Flow Tube Cover Plate.... Flush Optional
External Remote
Room Pressure Sensor .......... Flush Mounted |
|
Provides
new standards now required for room pressure monitors showing: |
|
Differential pressure (dP) in digital numerics 24/7 |
|
Flow direction |
|
Audible alarm when room pressure approaches ambient or reference
pressure |
|
|
|
Visual
alarm when room pressure approaches ambient barometric or
reference pressure |
|
|
|
Can
directly interface with in-house building digital automation
information. Systems is accurate to within ±0.001 inches
of WC with NIST traceable standards |
|
|
|
Can be flush
mounted to the wall or simply mounted on the wall |
|
|
|
Is simple to
install usually by house maintenance staff or electrician
|
|
|
|
Provided by
a nationwide company specializing in medical related
indoor air quality issues for the healthcare industry
|
|
|
|
Company can provide for
customer support number, availability 24/7 |
|
|
|
Small
conservative wall fixture, a compact, (4” W x 6” H x 2” D) unit
Is available for direct access to negative
or positive pressure rooms (TKFMS1630D) or a remote
model for room/s with anterooms or other sites, (TKFMS1630R).
Is also
available as a dual sensor model TKFMS1630-R2 for
measuring two rooms simultaneously with one unit. |
|
|
|
All models
are available as LON modified (TKFMS1630L-R2) for
interfacing with other systems. |
|
|
|
Adjustable
time delay for alarms allowing patients or staff moving in or
out of room |
|
|
|
Console
panel for remote installation and monitoring at nursing station
is available as an option |
|
|
|
Alpha/numeric programmable LCD readout on face of the control
panel |
|
|
|
Stainless
steel senor panel covers for both reference site and sensing
site |
|

PCPM1000 Room Pressure Monitor
Basic Room Pressure Monitor
|
The PCPM1000
monitor meets or exceeds all published AIA, CDC, JCAHO and HICPAC-2003
guidelines, standards and regulations.

Electrical
Power
Supply (provided) - 120 VAC to 24 VAC/DC
Remote Sensor
Distance - 400 feet max.
Remote Sensor
Wiring - 18-22 AWG twisted shielded copper pair
120 VAC to 24
VDC Power Supply Provided |
Mechanical
LCD Display -
4-digit LED x 8 characters
LCD Character
Height - 0.5 inches |
Mounting
PCPM1000......
Surface / Flush optional
Flow Tube Cover Plate.... Flush Optional
External Remote
Room Pressure Sensor .......... Flush Mounted |
|
Provides
new standards now required for room pressure monitors showing: |
|
Differential pressure (dP) in digital numerics 24/7 |
|
Flow direction |
|
Audible alarm when room pressure approaches ambient or reference
pressure |
|
|
|
Visual
alarm when room pressure approaches ambient barometric or
reference pressure |
|
|
|
Can
directly interface with in-house building digital automation
information. System is accurate to within ±0.001 inches of
WC with NIST traceable standards |
|
|
|
Can be flush
mounted to the wall or simply mounted on the wall |
|
|
|
Is simple to
install usually by house maintenance staff or electrician
|
|
|
|
Provided by
a nationwide company specializing in medical related
indoor air quality issues for the healthcare industry
|
|
|
|
Company can provide for customer support number, availability
24/7 |
|
|
|
Small
conservative wall fixture, a compact, (9.5"W
x 5.5"H x 2.0"D)
unit I |
|
|
|
Adjustable
time delay for alarms allowing patients or staff moving in or
out of room |
|
|
|
Console
panel for remote installation and monitoring at nursing station
is available as an option |
|
|
|
Alpha/numeric programmable LED readout on face of the control
panel |
|
|
|
Stainless
steel senor panel covers for both reference site and sensing
site |
|

AirShield™
DY475-000, Portable Digital Manometer
This hand-held portable manometer is a
compact, bi-directional, battery-operated, digital manometer with excellent
sensitivity and stability down to 0.001"of water column (or 0.1 Pascal). The
sensing element is a proprietary, highly sensitive, differential capacitance
cell, designed to operate at extremely low pressures. This sensing element has
been used for many years in other pressure transmitters and has proved to be
most reliable. This sensing element is used for pressures below 1.00 inch of
water column. Pressures greater than 1 inch of water is sensed by the latest
silicon based technology.
Performance
|
Electrical Connections
|
|
Resolution:
0-1.00
in W.C. (0-.249 kPa) |
Low battery indicator:
“BAT" appears on the display |
|
Accuracy:
±
0.5% FS 60 to 78degrees
|
Battery:
One (1) 9 Volt alkaline… not included |
|
± 1.5% FS 32 to 60 degrees |
Battery life:
100 hours |
|
± 1.5% FS 78 to 104 degrees
|
Physical |
|
Pressure Hysteresis:
±
0.1% of full scale |
Display:
LCD, .1/2" digit height |
|
Pressure Limits:
10 in. W. C. |
Controls:
ON/OFF switch, English-Metric unit selection readout
|
|
Zero Adjustment:
Zero adjustment knob at top |
Physical dimensions:
6-9/16”H, 2-13/16”W and 29/32”D |
|
Environmental |
Operating temp. range:
32 °F to 104°F |
|
Operating temp. range:
32
°F to 104°F |
Display:
LCD, .1/2" digit height |
|
Storage temp. range:
-4 °F to 176 °F |
Weight:
10.8 oz (306 g) |
|
 |

UV-C Radiometer
The X9 radiometer is a universally applicable
measuring instrument for the determination of UV-C irradiance at 254 nm
with direct read-out in the units of µW/cm2. The meter is used
together with the UV-3718 detector head to measure irradiance and dose
in the UV-C spectral range at 254nm. Despite its compact dimensions, the
meter offers a large display and an RS 232 interface. Operation is
simple for the benefit of non-technical personnel.
This unit ships complete with a protective case for the meter and
detector head.


|
Instrument
Specifications
- Max.
irradiance value · 1000 mW/cm2
- Max.
resolution · 0.001 µW/cm2
- Dose range
· 0.00001 J/cm2 to 100,000 J/cm2
-
Optometer
Specifications:
- Display ·
LCD, 6 characters, 9 mm high
- Detector
connection · 9 pol. MDSM9 socket, two measurement input
-
Measurement ranges · 9, selected automatically
-
Integration time · 500 ms
- Operating
modes· CW, Dose, Run/Stop, Peak
- Dosage
measurement · Integration of the measured values at 1s/100ms
intervals, Start/Stop by key-press
- Offset ·
Offset compensation over all ranges
- Operation
· 3 buttons, settings stored in eeprom
- Interface
· RS232 (9600B, 8D, 1S, N), 8 pin plug (Hirose, type 3260-8S!)
- Power · 9V
one-piece battery (operating time about 100 hrs)
-
Temperature range · 5 to 40°C (41-104°F)
- Size /
Weight · 120 mm x 65 mm x 22 mm / 150g (4.7 in x 2.6 in x 1 in / 0.3
lb)
|

|