Products and Services List
WARRANTY
5 years from date of delivery
Note on top
exhaust vs side exhaust:
Top exhaust needs a minimum of 30 between the false ceiling and hard deck.
Side exhaust needs a minimum of 24 from false ceiling to hard deck.
Note on
electrical requirements:
The motors on these blowers will operate at 50 or 60 Hz at 120 VAC that is
inverted to VDC. Call the MAS
office if a different voltage is required. This includes a compatible plug
configuration if that option is selected.
|
AS500CG-NP |
Ceiling mounted
model to create Negative Room Pressure |
|
Field #2 |
NP
= Negative pressure |
|
Field #2 |
RC
= Recirculating unit (Air into unit ducted to room diffusers) |
|
Field #3 |
SS =
All Stainless Steel Unit (Call for pricing) |
|
Field #4 |
115/60/1
inverted to 24 VDC, = Designate H = Hardwired
(Standard) or P = Plug |
|
Field #5 |
GP =
Custom color
powder coated grille (NP and RC units ONLY) |
|
Field #5 |
EW =
Eggshell White
diffuser-grille |
|
Field #6 |
TE
= Top Exhaust duct (Standard N/C) SE = Side
Exhaust duct |
|
|
|
AS900CG-NP |
Ceiling mounted
model to create Negative Room Pressure |
|
Field #2 |
NP
= Negative pressure |
|
Field #2 |
RC
= Recirculating unit (Air into unit ducted to room diffusers) |
|
Field #3 |
SS =
All Stainless Steel Unit (Call for pricing) |
|
Field #4 |
115/60/1
inverted to 24 VDC, = Designate H = Hardwired
(Standard) or P = Plug |
|
Field #5 |
GP =
Custom color
powder coated grille (NP and RC units ONLY) |
|
Field #5 |
EW =
Eggshell White
diffuser-grille |
|
Field #6 |
TE
= Top Exhaust duct (Standard N/C) SE = Side
Exhaust duct |
|
|
|
AS500CG-PP |
Ceiling mounted
model to create Positive Room Pressure |
|
Field #2 |
PP
= Positive pressure |
|
Field #2 |
RC
= Recirculating unit (Air from room grilles to unit) |
|
Field #3 |
SS =
All Stainless Steel Unit (Call for pricing) |
|
Field #4 |
115/60/1
inverted to 24 VDC, = Designate H = Hardwired
(Standard) or P = Plug |
|
Field #5 |
GP =
Custom color
powder coated grille (NP and RC units ONLY) |
|
Field #5 |
EW =
Eggshell White
diffuser-grille |
|
Field #6 |
TI
= Top Inlet duct (Standard N/C) SI = Side
Inlet Duct |
| |
|
|
AS900CG-PP |
Ceiling mounted
model to create Positive Room Pressure |
|
Field #2 |
PP
= Positive pressure |
|
Field #2 |
RC
= Recirculating unit (Air from room grilles to unit) |
|
Field #3 |
SS =
All Stainless Steel Unit (Call for pricing) |
|
Field #4 |
115/60/1
inverted to 24 VDC, = Designate H = Hardwired
(Standard) or P = Plug |
|
Field #5 |
GP =
Custom color
powder coated grille (NP and RC units ONLY) |
|
Field #5 |
EW =
Eggshell White
diffuser-grille |
|
Field #6 |
TI
= Top Inlet duct (Standard N/C) SI = Side
Inlet Duct |
All
ceiling units come with SS grilles or SS laminar airflow diffusers
standard. A wall mounted digital control panel is included with each unit.
WARRANTY
3 years from date of delivery
Note on top
exhaust vs side exhaust:
Top exhaust needs a minimum of 30 between the false ceiling and hard deck.
Side exhaust needs a minimum of 24 from false ceiling to hard deck.
Note
on electrical requirements:
The motors on these blowers will operate at 50 or 60 Hz at 120 VAC that is
inverted to VDC. Call the MAS
office if a different voltage is required. This includes a compatible plug
configuration if that option is selected.
|
AS500CSG-NP |
Ceiling mounted
model to create Negative Room Pressure |
|
Field #2 |
NP
= Negative pressure |
|
Field #3 |
SS =
All Stainless Steel Unit (Call for pricing) |
|
Field #4 |
115/60/1
inverted to 24 VDC,
Hardwired |
|
Field #6 |
TE
= Top Exhaust duct (Standard N/C) SE = Side
Exhaust duct |
|
|
|
AS900CSG-NP |
Ceiling mounted
model to create Negative Room Pressure |
|
Field #2 |
NP
= Negative pressure |
|
Field #3 |
SS =
All Stainless Steel Unit (Call for pricing) |
|
Field #4 |
115/60/1
inverted to 24 VDC,
Hardwired |
|
Field #6 |
TE
= Top Exhaust duct (Standard N/C) SE = Side
Exhaust duct |
Note:
These stainless steel grills incorporate a tamper
proof bolt fastener which require a special tool to unfasten when changing
filters.
All
ceiling units come with SS grilles or SS laminar airflow diffusers
standard. A wall mounted digital control panel is included with each unit.
AirShield EG
Series:
Exterior Duct Systems
WARRANTY
3 years from date of delivery
|
AS2000EG |
Exterior
model installed on a roof, curb, exterior wall, slab or legs
(legs provided) |
|
Field #2 |
NP
= Negative pressure, PP = Positive pressure or RC
= Recirculating unit |
|
Field #3 |
SS
= Stainless Steel Case (Call for pricing) |
|
Field #4 |
230/60/3 =
inverted to 24 VDC
(Other power configurations available) |
|
|
|
|
AS3500EG |
Exterior
model installed on a roof, curb, exterior wall, slab or legs
(legs provided) |
|
Field #2 |
NP
= Negative pressure, PP = Positive pressure or RC
= Recirculating unit |
|
Field #3 |
SS
= Stainless Steel Case (Call for pricing) |
|
Field #4 |
230/60/3 =
inverted to 24 VDC
(Other power configurations available) |
| |
|
|
AS5000EG |
Exterior
model installed on a roof, curb, exterior wall, slab or legs
(legs provided) |
|
Field #2 |
NP
= Negative pressure, PP = Positive pressure or RC
= Recirculating unit |
|
Field #3 |
SS
= Stainless Steel Case (Call for pricing) |
|
Field #4 |
230/60/3 =
inverted to 24 VDC
(Other power configurations available) |
A wall
mounted all digital control panel is included with each unit.
These external units are specially insulated (R-10 Insulation board) for
outdoor use/noise reduction and are provided with L-iron frame & legs
|
AS2000DG |
Interior model
installed in a remote location such as in electrical/mechanical room |
|
Field #2 |
NP
= Negative pressure, PP = Positive pressure or RC =
Recirculating unit |
|
Field #3 |
SS
= Stainless Steel Case (Call for pricing) |
|
Field #4 |
230/60/3 =
inverted to 24 VDC
(Other power configurations available) |
| |
|
|
AS4000DG |
Interior model
installed in a remote location such as in electrical/mechanical room |
|
(Field 2) |
NP
= Negative pressure, PP = Positive pressure or RC =
Recirculating unit |
|
(Field 3) |
SS
= Stainless Steel Case (Call for pricing) |
|
(Field 4) |
230/60/3 =
inverted to 24 VDC
(Other power configurations available) |
These
units are specially insulated (R-10 Insulation board) for noise reduction.
A wall mounted all digital control panel is included with each unit.
AirShield MG Series, Mobile APS
WARRANTY 3
years from date of delivery
|
AS1000MG |
Mobile (formally
called a Portable) Model Powder coated carbon steel w/ hospital
grade plug |
|
Field #2 |
UV
= UVGI |
|
Field #3 |
SP
= Special Powder Coated (Supply color chip or angstrom) |
|
Field #4 |
115/60/1
inverted to 24 VDC
Standard (Other power configurations available) |
Powder
coated computer tan is standard with hospital grade plug is also standard.
APT 625P Mobile
WARRANTY 1
year from date of delivery
|
APT625P |
Standard Model -
Recirculating model with UVGI installed |
|
Field #2 |
NP
= Convertible- negative pressure hood add-on (10 collar) |
|
Field #3 |
UV
= UV-C, Single Lamp Bracket & bulb not installed |
|
Field #4 |
115/60/1
= Standard Indicate alternate power requirements (Call for
pricing) |
The
above is the model number for a basic unit with no options.
WARRANTY
1 year from date of delivery
|
AirShield 4000, GBM |
Postal Inspection Unit |
The
above is the model number for a basic unit with no options.
|
20 Gallon
Vacuum |
SS Dry
Only, 2.25 HP HEPA Vacuum w, Tool Kit - Many Accessories
available |
|
20 Gallon
Vacuum |
SS Wet, Dry,
2.25 HP HEPA Vacuum w, Tool Kit - Many Accessories available |
MAS AirShield
Construction APS Series
WARRANTY
1 year from date of delivery
Construction
Commercial/Bioterror Air Scrubbers APS
|
ST500-CAP |
500 CFM on HIGH, 3
speed |
|
ST500-CAP-UV |
500 CFM on HIGH, 3
speed |
|
Inlet Port |
Side door add-on
available |
|
|
|
|
ST2000-CAP |
2000 CFM on HIGH, 3
speed |
|
ST2000-CAP-UV |
2000 CFM on HIGH, 3
speed) |
|
Inlet Port |
Side door add-on
available |
|
|
|
|
ST4000-CAP |
4000 CFM on HIGH, 3
speed |
|
ST4000-CAP-UV |
4000 CFM on HIGH, 3
speed) |
|
|
|
|
Hour Meter for Above |
Hour meter to track run time available |
WARRANTY
1 year from date of delivery
|
F111A1063 |
|
|
F111C1012 |
|
|
F111C1073 |
|
|
F111U1063 |
|
|
F112A6003 |
|
|
F112C6001 |
|
|
F113A6001 |
|
|
F113C6009 |
|
|
F114A1067 |
|
|
F114C1008 |
|
|
F115A1064 |
|
|
F115C1005 |
|
|
F116A1120 |
|
|
F116A1121 |
|
|
F118C1009 |
|
|
F120A1023 |
|
|
F120A1031 |
|
|
F57A1044 |
|
|
F57B1026 |
|
|
F90A1050 |
|
MAS Portable APS Series
WARRANTY
5 year from date of delivery
PORTABLE
UNITS
Health Pro
Series For
medical offices, ER departments, emergency treatment rooms. Physician
waiting rooms, etc.
Health Pro Compact
|
Stand-up, professional, 2 stage floor model, 22" high (55% ASHRAE-
MERV-7) pre-filter & 99.97% HEPA filter) |
|
|
Certified HEPA
filter, 99.97%
No. 102-14-14-00 |
|
|
Replacement
Pre-filter, 55% ASHRAE (MERV-7) No. 102-10-10-00 |
|
|
|
|
Health Pro
|
Stand-up, professional, 2 stage floor model, 28" high (55% (MERV-7)
ASHRAE pre-filter & 99.97% HEPA filter) |
|
|
Certified HEPA
filter, 99.97%
No. 102-14-14-00 |
|
|
Replacement
Pre-filter, 55% ASHRAE (MERV-7) No. 102-10-10-00 |
|
|
|
|
Health Pro Plus
|
Stand-up, professional, 2 stage floor model, 28" high (55% (MERV-7)
ASHRAE pre-filter & 99.97% HEPA filter) |
|
Certified HEPA
filter, 99.97%
No. 102-14-14-00 |
|
Replacement
Pre-filter, 55% ASHRAE (MERV-7) No. 102-10-10-00 |
|
HiFlow V-cell5
gas & odor filter
No. 102-18-10-00 |
|
Upgrade Gas
module from a HealthPro No. 102 18 10 50 |
GC Series
For
low to medium VOC risk areas
GC VOC
|
Advanced floor model 28" high for volatile gas, particulate &
particulate removal, 3 stage |
|
4 Statically
charged post filter sleeves No. 102-50-10-00 |
|
4 Extruded
activated carbon gas filters No. 102-40-10-00 |
|
Pre-filter 98%
HEPA type filter No.
102-10-12-00 |
GC Multigas
|
Advanced floor model 28" high for multi-gas, particulate &
particulate removal, three stage |
|
4 Statically
charged post filter sleeves No.
102-50-10-00 |
|
4 Granular wide
spectrum gas control filters No. 102-40-16-00 |
|
Pre-filter 98%
HEPA type filter
No. 102-10-12-00 |
GC Chemisorber
|
Advanced floor model 28" high for control of formaldehyde, hydrogen
sulfide, SO2.,etc. |
|
4 Statically
charged media pre-filer 99%. No.
102-50-10-00 |
|
4 Granular
chemsorbant gas phase filters No. 102-40-18-00 |
|
Pre filter
(H-11S) 98% HEPA type filter No.
102-10-12-00 |
GC AM
|
Advanced floor model 28" high, for control of ammonia, amines
ammonia based odors, etc. |
|
4 Statically
charged media pre-filer 99% . No. 102-50-10-00 |
|
4 Extruded,
impregnated activated carbon filters No. 102-40-14-00 |
|
Pre filter
(H-11S) 98% HEPA type filter No. 102-10-12-00 |
GCX Series
(heavy duty)
For
high risk VOC areas.
GCX VOC
|
Advanced floor model 40" high for volatile gas, particulate &
particulate removal, three stage |
|
4 Statically
charged post filter sleeves No. 102-50-50-00 |
|
4 Extruded
activated carbon gas filters No. 102-42-10-00 |
|
Pre-filter 98%
HEPA type filter No.
102-14-11-00 |
GCX Multigas
|
Advanced floor model 40" high for multi-gas, particulate &
particulate removal, three stage |
|
4 Statically
charged post filter sleeves No.
102-50-50-00 |
|
4 Granular wide
spectrum gas control filters No. 102-42-16-00 |
|
Pre-filter 98%
HEPA type filter
No. 102-14-10-00 |
GCX Chemisorber
|
Advanced floor model 40" high for control of formaldehyde, hydrogen
sulfide, sulfur dioxide, etc. |
|
4 Statically
charged media pre-filer 99%. No.
102-50-50-00 |
|
4 Granular
chemsorbant gas phase filters No. 102-42-18-00 |
|
Pre filter
(H-11S) 98% HEPA type filter No.
102-14-11-00 |
GCX AM
|
Advanced floor model, 40"high, for control of ammonia, amines
ammonia based odors. |
|
4 Statically
charged media pre-filer 99%. No. 102-50-50-00 |
|
4 Extruded ,
impregnated activated carbon filters No. 102-42-14-00 |
|
Pre filter
(H-11S) 98% HEPA type filter No.
102-14-11-00 |
Dental
Series
Also
Ideal for laser surgicenters and plastic surgeons suites
Dental Pro
|
For
control of VOCs microbiological contaminants and odors |
|
Post filter
electrostatically charged Type P260 F8 No. 102-50-10-00 |
|
Gas filter
cartridge set, Type 260 No. 102-40-50-00 |
|
Pre-filter 98%
HEPA type No.
102-10-12-00 |
Dental Hg FlexVac
|
For
control of drill aerosols, mercury vapors and microbiological
contaminants and odors |
|
Post filter
electrostatically charged Type P260 F8 No. 102-50-10-00 |
|
Gas filter
cartridge set, Type 260 No. 102-40-12-00 |
|
Pre-filter 98%
HEPA type No.
102-10-12-00 |
Clean Room Series
Cleanroom Model H-13
|
Professional Floor model, 32 high, for waiting rooms, treatment
Rooms, etc. Clean rooms up to class 7,000 |
|
HEPA 99%
clean-room grade, Type H11-LQ No. 102-16-13-00 |
|
Pre-Filter at 55%
(MERV-7) Type FS-L No. 102-14-10-00 |
IQ Air
Accessories
VM Flex Vac
|
Wall mountable
Self-supporting Suction Duct Assembly.
No. 108 32 99 20 |
FlexVac
|
Mobile Flexible, Self-supporting Suction Duct Assembly. Arm length
five (5)
feet
No. 108 10 99 20 |
|
In Flow
W125 |
Inflow ducting
Kit with Wall Vent No. 108
20 99 20 |
|
Outflow
W125 |
Outflow ducting
Kit with Wall Vent No. 108 25
99 20 |
|
Base
Ext. Kit |
For increased
mobility and air intake Mobility 56
|
|
Side
Panel Kit Control Unit |
For replacing the
side brackets with the control unit VMF. On top to side
panels with control unit on side at bottom & wall mount fixtures |
Room Pressure Monitors Select Comm. protocol (BACnet, MODBUS, N2, etc.)
WARRANTY
2 years from date of delivery
|
TKFMS1630-D |
Room
Pressure Monitor with local sensor # 0-010-0 |
|
TKFMS1630-LON-T |
Room
Pressure Monitor with local sensor & Temp control |
|
TKFMS1630-LON-H |
Room
Pressure Monitor with local sensor & Humidity control |
|
TKFMS1630-LON-HT |
Room
Pressure Monitor with local sensor & Temp. / Humidity Cont.
|
|
TKFMS
1630-LON-PHT |
Room
Pressure Monitor w/ local sensor for Temp, Press & Hum. |
|
TKFMS1630-NRS |
Room Pressure
Monitor w/ remote sensor telemetry capability |
|
TKFMS1630-R |
Room Pressure
Monitor w/ remote sensor # 0-010-1 |
|
TKFMS1630-RD |
Room Pressure
Monitor w/ remote & direct sensor # 0-010-3 |
|
TKFMS1630-R2 |
Dual Room Pressure
Monitor w/ two (2) remote sensor # 0-010-2 w/LON |
|
TKFMS1630-Barb-Kit |
Tube expansion kit
for remote models (⅜ to พ tubing) |
|
TKFMS Flush-mount
Plate |
Room pressure face plate mounted flush to wall no box |
|
TKFMS1630-Key |
Replacement security
key |
|
TKFMS1630-Key-M |
Key lock switch
assembly |
|
TKFMS1630XFMRUL |
Replacement AC 12V
transformer |
|
Calibration |
Calibration performed only at
manufacturer's lab |
AirShield
Room Pressure Monitors
WARRANTY
2years from date of delivery
|
PCPM1000 |
Room Pressure
Monitor * |
|
PCPM2000 |
Room Pressure
Monitor w/ controller* |
|
PCPM- Key |
Large Barrel Key,
Replacement for ASPM models |
|
PCPM Surface mount |
Plate for
mounting monitor flush to wall |
* NOTE: All these monitors have
remote capability built-in, there is no direct model as such. Calibration
is performed in the field.
NEW
Touch-Screen Room Monitors (CRC)
(Pressure.-Temperature- Humidity)
Select Comm. protocol (BACnet, MODBUS,
N2, etc.)
WARRANTY
1 year from date of delivery
|
TRRM |
Touch-screen
monitor reports Temp.-Pressure & rH- w/ sensors |
|
TRCD |
Senses pressure
and initiates safety protocols/displays for room |
|
TRMD |
Central
Monitoring station for up to four (4) rooms (ie. Nurses Loc.) |
|
TRRMD |
Combination of
TRRM & TRMD |
Fume
Hood Flow Monitors
WARRANTY
1 year from date of delivery
|
TKHMS1600D |
Hood controller /
monitor / dual sensor |
|
TKHMS1600S |
Hood controller /
monitor / single sensor |
|
TKACT-FA-8001 |
Electric actuator
& and transformer power supply |
Triatek can provide
complete hood control and lab ventilation systems. Call for specific
information
Measuring
Equipment
WARRANTY
1 year from date of delivery
|
IQ ParticleScan
CR |
For professional
particulate measurements in clean rooms / software |
|
IQ ParticleScan
Pro |
For professional
particulate measurements 6 ranges, 0.3 microns and higher |
|
IQ ParticleScan
Lite |
For Basic
particulate measurements (1 range - 0.3 Micron & up) |
|
HW C7242 |
CO2
Sensor / Monitor wall mounted (Quantity prices available) |
|
HW F117 |
Hand held laser
digital particle counter (1 range - 0.3 Micron & up) |
|
LU
X-9 |
Hand held Digital
Radiometer for UV-C measurement |
|
DW
475-000
FM-AV |
Hand held
pressure monitor. w/ plastic carrying kit and accessories.
Accuracy @ 0.001 W. C. = ฝ% |
|
DW
475-000 FM |
Hand held
pressure monitor w/ cloth carrying case. Accuracy @ 0.001 W.
C. = ฝ% |
|
DW
475-000 Kit |
Plastic carrying
case w/ accessories for portable pressure monitor |
|
DW
475-000 cloth |
Cloth carrying
case only for DW 475-000 |
|
MTIN-6 Air Sampler |
Active
impact air sampler w/ pump, sampler & stand. Agar plates available. |
|
AS
69-V-ADI Ball-in-tube |
Visual
ball-in-tube over door pressure +/- Indicator |
|
DWF641-12R Flowmeter |
Digital air
velocity flow meter |
WARRANTY
3 Years
For Class A Surgical Suites
The
CORAD A
A laminar airflow system for a
small
operating room.
CORAD A System
(Aluminum case with SS laminar
airflow grille)
|
Consisting of: two (2) AS900GC-PP-UV (48 x 24) Certified 99.99% HEPA
w/ SS laminar flow diffuser system with digital controllers. One
(1) Room temperature, pressure, relative humidity touch screen
monitor. Air provided will be by motor-blower fans driven by the two
(2) AS900GC units positioned bilaterally over the surgical table to
ensure correct laminar flow CFM delivery for
15 ACH for a room size of
16x18x9 (2,592 cubic feet).
Price does not include a sealed ceiling!
Price of a sealed cleanroom operating room ceiling of 288 sq. ft is an
additional: |
The
CORAD A
A laminar airflow system for a
large operating room.
CORAD A System
(Aluminum case with SS laminar
airflow grille)
|
Consisting of: two (2) AS900GC-PP-UV (48 x 24) Certified 99.99% HEPA
w/ SS laminar flow diffuser system with digital controllers. One
(1) Room temperature, pressure, relative humidity touch screen
monitor. Air provided will be by motor-blower fans driven by the
two (2) HEPA AS900GC units positioned bilaterally over the surgical
table within the plenum to ensure correct laminar flow delivery for
15 ACH for a room size of
18x24x9 (3,888 cubic feet)
Price does not include a sealed ceiling!
Price of a sealed cleanroom operating room ceiling of 422 sq. ft is an
additional: |
For Class B Surgical Suites
The
CORAD B
A laminar airflow system for a
small operating room.
CORAD B System
(Aluminum case with SS laminar
airflow grille)
|
Consisting of: four (4) AS900GC-PP-UV (48 x 24) Certified 99.99% HEPA
w/ SS laminar flow diffuser system with digital controllers. One
(1) Room temperature, pressure, relative humidity touch screen
monitor. Air provided will be by motor-blower fans driven by the
four (4) AS900GC units positioned bilaterally over the surgical
table and at the foot and head of the surgical table to ensure
correct laminar flow CFM delivery for 25
ACH for a room size of 20x26x9
(4,680 cubic feet). Four (4) wall mounted UVGI WM136. Each
unit covers up to 240 sq. ft.
Price does not include a sealed ceiling! Price of a sealed cleanroom
operating room ceiling of 520 sq. ft is an additional: |
The
CORAD B
A laminar airflow system for a
large
operating room.
CORAD B System
(Aluminum case with SS laminar
airflow grille)
|
Consisting of: four (4) AS900GC-PP-UV (48 x 24) and two (2)
AS900GC-PP-UV (24 x 24) Certified 99.99% HEPA w/ SS laminar flow
diffuser system with digital controllers. One (1) Room temperature,
pressure, relative humidity touch screen monitor. Air provided will
be by motor-blower fans driven by the six (6) AS900GC units
positioned bilaterally over the surgical table and the AS500CG units
at the foot and head of the surgical table to ensure correct laminar
flow CFM delivery for 25 ACH for a
room size of 24x30x9 (6,480 cubic feet).
Four (4) wall mounted UVGI WM136 units. Each unit covers up to 240
sq. ft.
Price does not include a sealed ceiling! Price of a sealed cleanroom
operating room ceiling of 720 sq. ft is an additional: |
For Class C Surgical Suites
The
CORAD C
has all elements of
a CORAD B with a
protective air curtain
for a typical operating room
CORAD C System
(Aluminum duct) w/ peripheral air
curtain
|
A circumferential
duct in the upper plenum supplying air to Linear Slot Diffusers for
an Air Curtain around the periphery of the operating table
(w/Control Dampers) Price does not include sealed ceiling.
Direct UV-C
irradiation is available as an optional cost. |
|
Stainless Steel CORAD
Systems |
CORAD Systems
with 304 stainless steel construction
of specific elements
|
All CORAD system
can have elements constructed of 304 stainless steel (SS). The
elements include:
v
MAHS systems with 304 SS case (Diffusers are already 304 SS)
v
All 304 SS hard ducting (Standard is aluminum)
v
All 304 SS Linear Slot Diffusers (for air Curtain)
v
All 304 SS upper room UVGI units |
MAS
Medical UVGI Fixtures
WARRANTY
2 years from date of delivery
Wall
Mounted TB Series
AUTB-12-W
|
Covers 100 sq. ft. 12 Horizontal mounted SS fixture
|
AUTB-24-W
|
Covers 200 sq.
ft. 24 Horizontal mounted SS fixture |
|
AUTB-36-W |
Covers 300 sq.
ft. 36 Horizontal mounted SS fixture |
|
AUCM-15-W |
Covers 150 sq.
ft. Corner mounted SS fixture |
|
|
|
|
|
LAMP REPLACEMENTS |
|
SBL060 |
Lamp replacement
for AUTB-12-W |
SBL325
|
Lamp replacement
for AUTB-24-W |
SBL005
|
Lamp replacement
for AUTB-36-W |
GML500
|
Lamp replacement
for AUCM-15-W |
Clean-Duct,
Horizontal, Duct Insert Fixtures
2 lamp, - 4 Lamp
DC14-2-120
|
14
Duct mounted fixture w/ 2 lamps 120V |
DC16-2-120
|
16
Duct mounted fixture w/ 2 lamps 120V |
DC24-2-120
|
24
Duct mounted fixture w/ 2 lamps 120V |
DC33-2-120
|
33
Duct mounted fixture w/ 2 lamps 120V |
DC45-2-120
|
45
Duct mounted fixture w/ 2 lamps 120V |
DC14-4-120
|
14
Duct mounted fixture w/ 4 lamps 120V |
DC16-4-120
|
16
Duct mounted fixture w/ 4 lamps 120V |
DC24-4-120
|
24
Duct mounted fixture w/ 4 lamps 120V |
DC33-4-120
|
33
Duct mounted fixture w/ 4 lamps 120V |
DC45-4-120
|
45
Duct mounted fixture w/ 4 lamps 120V |
NOTE:
|
All Duct mounted
fixtures are available in 220V configuration |
|
|
|
LAMP REPLACEMENTS |
SBL410
|
Lamp for all DC14 Fixtures |
SBL430
|
Lamp for all DC16 Fixtures |
SBL415
|
Lamp for all DC24 Fixtures |
SBL420
|
Lamp for all DC33 Fixtures |
SBL445
|
Lamp for all DC45 Fixtures |
|
|
|
BALLASTS |
TXG270
|
Ballasts for all 120V Clean Duct Fixtures |
CC
Series Coil Clean Fixtures, 1 Lamp Units
Air
Handler Disinfection, Floor or Ceiling Mounted
(High
Output)
CC18-1-120C
|
18, 1-lamp fixture, end to end connection, 120V |
CC24-1-120C
|
24, 1-lamp fixture, end to end connection, 120V |
CC36-1-120C
|
36, 1-lamp fixture, end to end connection, 120V |
CC48-1-120C
|
45, 1-lamp fixture, end to end connection, 120V |
CC60-1-120C
|
60, 1-lamp fixture, end to end connection, 120V |
|
|
|
|
2540-15B |
Junction Box (one
required per row) |
|
2540-18 |
Row end cap ( 1
per row) |
|
|
|
CC18-1-120
|
18, 1-lamp fixture, hardwire connection, 120V |
CC18-1-120
|
18, 1-lamp fixture, hardwire connection, 120V |
CC18-1-120
|
18, 1-lamp fixture, hardwire connection, 120V |
CC18-1-120
|
18, 1-lamp fixture, hardwire connection, 120V |
CC18-1-120
|
18, 1-lamp fixture, hardwire connection, 120V |
|
|
|
|
Cordkit |
120V, 8 power
cord w/strain relief |
|
|
|
|
|
CC Lamp
Replacements / Ballasts |
|
GCL-18 |
Lamp for all CC18
Fixtures |
|
GCL-24 |
Lamp for all CC24
Fixtures |
|
GCL-36 |
Lamp for all CC36
Fixtures |
|
GCL-48 |
Lamp for all CC45
Fixtures |
|
GCL-60 |
Lamp for all CC60
Fixtures |
|
|
|
|
TXG270 |
Ballast for 120V
fixtures (except the CC60) |
|
TXG285 |
Ballast for 120V
CC60 Fixtures |
CC
Series Coil Clean Fixtures, 2 Lamp Units
Air
Handler Disinfection, Floor or Ceiling Mounted
(High
Output)
CC18-2-120C
|
18, 2-lamp fixture, end to end connection, 120V |
CC24-2-120C
|
24, 2-lamp fixture, end to end connection, 120V |
CC36-2-120C
|
36, 2-lamp fixture, end to end connection, 120V |
CC48-2-120C
|
45, 2-lamp fixture, end to end connection, 120V |
CC60-2-120C
|
60, 2-lamp fixture, end to end connection, 120V |
|
|
|
|
2540-15B |
Junction Box (one
required per row) |
|
2540-18 |
Row end cap ( 1
per row) |
|
|
CC18-2-120
|
18, 2-lamp fixture, hardwire connection, 120V |
CC18-2-120
|
18, 2-lamp fixture, hardwire connection, 120V |
CC18-2-120
|
18, 2-lamp fixture, hardwire connection, 120V |
CC18-2-120
|
18, 2-lamp fixture, hardwire connection, 120V |
CC18-2-120
|
18, 2-lamp fixture, hardwire connection, 120V |
|
|
|
|
Cordkit |
120V, 8 power
cord w/strain relief |
|
|
|
|
|
CC Lamp
Replacements / Ballasts |
|
GCL-18 |
Lamp for all CC18
Fixtures |
|
GCL-24 |
Lamp for all CC24
Fixtures |
|
GCL-36 |
Lamp for all CC36
Fixtures |
|
GCL-48 |
Lamp for all CC45
Fixtures |
|
GCL-60 |
Lamp for all CC60
Fixtures |
|
|
|
|
TXG270 |
Ballast for 120V
fixtures (except the CC60) |
|
TXG285 |
Ballast for 120V
CC60 Fixtures |
Surgical
Suite Indirect Irradiation Fixtures
AUTB-12-W
|
Covers 100 sq. ft. 12 Horizontal mounted SS fixture
|
AUTB-24-W
|
Covers 200 sq.
ft. 24 Horizontal mounted SS fixture |
|
AUTB-36-W |
Covers 300 sq.
ft. 36 Horizontal mounted SS fixture |
|
SBL060 |
Lamp replacement
for AUTB-12-W |
SBL325
|
Lamp replacement
for AUTB-24-W |
SBL005
|
Lamp replacement
for AUTB-36-W |
GML500
|
Lamp replacement
for AUCM-15-W |
RAM
Series, Motor/blower Assisted UVGI
RAM14-2-120
|
Enclosed , Fan assisted unit (2) 14 HO lamps 120V |
RAM36-2-120
|
Enclosed , Fan assisted unit (2) 36 HO lamps 120V |
|
|
|
Lamp Replacements for RAM series |
SBL410
|
Lamp for all 14 Ram 14 Units |
SBL420
|
Lamp for all 36 Ram Units |
Door
Barrier UVGI
DB-36
|
Door barrier fixture 1 36 120 |
|
|
|
Lamp replacement for DB units |
GML005
|
Lamp for DB -36 |
TXG10B
|
Ballast for DB -36 |
Safety
Equipment
SAF005
|
Ultra-GOG 300 , Safety goggles |
SAF010
|
Ultra Spec 100, Safety glasses |
SAF020
|
Visor GOGS, safety goggles with visor |
SAF015
|
Ultra Shield 200, full face shield |
SAF030
|
Solbar UV absorbing cream (2) 12 oz. tubes |
Recessed Troffer Fixtures
|
RT-2G/2CWE |
2 x 4 Recessed
Troffer w/ (2) 36 Slimline UVC lamps & 2 F30T12 Florescent lamps
for a drop in grid ceiling |
|
RT-2G/2CWM
|
2 x 4 Recessed
Troffer w/ (2) 36 Slimline UVC lamps & 2 F30T12 Florescent lamps
for a plaster ceiling |
|
RT-36-2G E |
2 x 4 Recessed
Troffer w/ (2) 36 Slimline UVC lamps for a drop in grid ceiling
|
|
RT-36-2G M
|
2 x 4 Recessed
Troffer w/ (2) 36 Slimline UVC lamps for a plaster ceiling
|
|
RT-36-4G E |
2 x 4 Recessed
Troffer w/ (4) 36 Slimline UVC lamps for a drop in grid ceiling
|
|
RT-36-4G M |
2 x 4 Recessed
Troffer w/ (4) 36 Slimline UVC lamps for a plaster ceiling
|
|
RT-36-2T- 1X4 |
1 x 4 Recessed
Troffer w/ (2) 36 Slimline UVC lamps for a drop in grid ceiling
|
|
|
Note: Specify voltage |
|
Replacement lamps for Recessed Troffer units |
GML005
|
36
Slimline Hot Cathode Quartz Lamp |
BLL095
|
Florescent Lamp for RT Fixtures |
|
Consult factor
for ballast for these units. |
NEW!
AirShield
Sputum Collection Booth
WARRANTY
1 year from date of delivery
|
ASSB500C-NP-UV |
Contains AS500GC-NP-UV,
ABU, & PCPM1000
|
|
Custom Sizes |
Larger units can be ordered in custom sizes |
MASIR
Custom Built Mail Inspection Rooms
WARRANTY
1 year from date of delivery
K-Con GSA
contract number is: 07F-0216L with a Federal SIN # of 631-10
Shipping,
structural assembly and engineering consultant fees are extra and quoted
separately
Indoor
MASIR
|
MASIR 225 |
225
sq. ft. Call for standard and GSA price. |
|
MASIR 384 |
384
sq. ft. Call for standard and GSA price. |
|
MASIR 560 |
560
sq. ft. Call for standard and GSA price. |
Outdoor
MASIR
|
MASIR 784 |
784
sq. ft. Call for standard and GSA price. |
|
MASIR 2080 |
2,080 sq. ft. Call for standard and GSA price. |
EPIC
Emergency
Preparedness Isolation
Center
WARRANTY
1 year from date of delivery
|
EPIC 1800 |
1,800 sq. ft. Call for standard and GSA price. (Larger
buildings available) |
AirShield
Pass Through Models
WARRANTY
1 year from date of delivery
Standard
Pass-Through Module
|
VTPT300 |
Contra-door lock,
pass thru unit. Stainless steel w/clear panel with interlocking
doors. Single chamber, no racks. 20W x 20D x 18H exterior, 17⅝W
x 18D x 15⅝H
interior |
Custom
Pass-Through Modules
|
VTPT200 |
Contra-door lock,
pass thru unit. Stainless steel w/clear pane with interlocking
doors. Single chamber, two sections and 3 racks. 12W x 20D x 18H
exterior, 9⅝W
x 18D x 15⅝H
interior |
|
VTPT400 |
Contra-door lock,
pass thru unit. Stainless steel w/clear pane and locking doors,
Single chamber with 3 racks. 18W x 24D x 36H exterior, 15⅝W
x 22D x 33⅝H
interior |
|
VTPT500 |
Contra-door lock,
pass thru unit. Stainless steel w/clear pane and locking doors,
Single chamber with 4 racks. 36W x 24D x 48H exterior, 33⅝W x 21D
x 45⅝H
interior |
|
VTPT600 |
Contra-door lock,
pass thru unit. Stainless steel w/clear pane and locking doors,
Single chamber with 3 racks. 24W x 36D x 36H exterior, 21⅝W x 34D
x 33⅝H
interior |
|
VTPT700 |
Contra-door lock,
pass thru cart. Stainless steel w/clear pane and locking doors,
Single chamber with 5 racks. 24W x 30D x 80H exterior, 21⅝W
x 27D x 78H interior |
|
VTPT800 |
Contra-door lock,
pass thru unit. Stainless steel w/clear pane and locking doors,
Two (2)
chambers with 5 racks each. 77-1/2W x 30D x 60H exterior, 36⅜W x 27D
x 58H interior |
|
VTPT900 |
Contra-door lock,
pass thru unit. Stainless steel w/clear pane and locking doors,
Two (2)
chambers with 3 racks each. 48W x 24D x 36H exterior, 13-⅝W
x 22D x 34H interior |
|
VTPT1000 |
Contra-door lock,
pass thru unit. Stainless steel w/clear pane and locking doors,
Four (4)
chambers with 5 racks each. 105W x 30D x 60H exterior, 23⅝W x
27-5/8D x 57⅝H
interior |
Pass
Through Refrigerators
- TempGuardฎ
Reach-In
Refrigerators
|
SUPTR1SSB-FGFG |
1-Section Pass
Through Refrigerator with Full Height Glass Doors 27.5 x 35.9 x
84.5 |
|
SUPTR1SSB-HGHG |
1-Section Pass
Through Refrigerator with Half Height Glass Doors 27.5 x 35.9 x
84.5 |
|
SUPTR2SSB-FGFG |
2-Section Pass
Through Refrigerator with Full Height Glass Doors 55 x 35.9 x
84.5 |
|
SUPTR2SSB-HGHG |
2-Section Pass
Through Refrigerator with Half Height Glass Doors 55 x 35.9 x
84.5 |
Reach-In
Refrigerators
(Door on one side only)
|
SURH1-SSB-FG |
1-Section Reach-In
Refrigerator with Full Height Glass Doors 27.5 x 33.6 x 84.5 |
|
SURH1-SSB-HG
|
1-Section Reach-In
Refrigerator with Half Height Glass Doors 27.5 x 33.6 x 84.5 |
|
SURH2-SSB-FG |
2-Section Reach-In
Refrigerator with Full Height Glass Doors 55.0 x 33.6 x 84.5 |
|
SURH2-SSB-HG |
2-Section Reach-In
Refrigerator with Half Height Glass Doors 55.0 x 33.6 x 84.5 |
|
SURH3-SSB-FG |
3-Section Reach-In
Refrigerator with Full Height Glass Doors 82.5 x 33.6 x 84.5 |
|
SURH3-SSB-HG |
3-Section Reach-In
Refrigerator with Half Height Glass Doors 55.0 x 33.6 x 84.5 |
MAS can
supply other types of refrigerators including those designed to provide ice
for patients. Call MAS for more information at (800) 645-1059
|